Materiel:                                 Nylatron GSM
Tensile Strength at 23°C:       11,000-14,000 psi/7,750-9,850 kg/cm2
Mod. og Elast at 23°C:          350,000-450,000 psi/246,000-316,000 kg/cm2
Flexural Strength at 23°C:     15,000-15,800 psi/10,500-11,200 kg/cm2
Coef. of Lin. Exp.:                 100 x 10-6 mm/mm/°C/105 x 10-5 in/in/°F
Melting Point:                        220°C/428°F
Flammability:                         Self-extinguishing
Elect. Resistivity:                   1012 ohm/cm
Elec. Field Generation:          None
 
 
Bore
Inches
4 6 8 10 12 14 16
Outside Diameter
Inches
9 11 13½ 16 19 21 23½
PCD
Inches
11¾ 14¾ 17 18¾ 21¼
Length
Inches
55/8 55/8 6 6
No. of Bolts
No.
16 16 16 24 24 24 32
Bolt Hole Diameter
Inches
¾ 7/8 7/8 1 1 11/8 11/8
Test Pressure
psi
750 750 750 750 750 750 750
Longitudinal Stress
psi
600 1,121 1,333 1,408 1,273 1,656 1,608
 
Bolting dimensions conform to ASA 150.
Resistant to:    Most common solvents, lubricants, hydrocarbons, esters, ketones, and aqueous solutions of acids and alkulles at pH 5 to pH 11. See separate chemical resistance chart. Can be continuously PTFE-lined for more severe chemical services.